<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>KS Kondensatoren &#8211; DDR RFT Elektronik</title>
	<atom:link href="https://www.ddr-rft-elektronik.de/tag/ks-kondensatoren/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.ddr-rft-elektronik.de</link>
	<description></description>
	<lastBuildDate>Tue, 22 May 2018 04:24:32 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://www.ddr-rft-elektronik.de/wp-content/uploads/2024/01/cropped-favicon_rft_elektronik_2-32x32.jpg</url>
	<title>KS Kondensatoren &#8211; DDR RFT Elektronik</title>
	<link>https://www.ddr-rft-elektronik.de</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>KS Kondensatoren im Kunststoffgehäuse nach TGL 38158 und TGL 33965</title>
		<link>https://www.ddr-rft-elektronik.de/kondensatoren/ks-kondensatoren-im-kunststoffgehaeuse-nach-tgl-38158-und-tgl-33965/</link>
		
		<dc:creator><![CDATA[Andreas]]></dc:creator>
		<pubDate>Sat, 21 Jun 2014 09:26:50 +0000</pubDate>
				<category><![CDATA[Kondensatoren]]></category>
		<category><![CDATA[DDR Kondensatoren]]></category>
		<category><![CDATA[KS Kondensatoren]]></category>
		<category><![CDATA[Polystyrolkondensatoren]]></category>
		<guid isPermaLink="false">http://www.ddr-rft-elektronik.de/?p=252</guid>

					<description><![CDATA[Die KS Kondensatoren nach TGL 33965 und TGL 38158 sind Polystyrolkondensatoren in einem prismatischen Kunststoffgehäuse. Die Kondensatoren sind hochwertige Passivbauelemente der Elektronik und waren für die Anwendung in der kommerziellen Funk- und Fernmeldetechnik vorgesehen. Durch den Einbau der Kondensatorwickel in dem epoxidharzvergossenem Kunststoffbecher sind die KS-Kondensatoren sehr gut gegen Umwelteinflüsse geschützt, was sich sehr positiv auf ... <a title="KS Kondensatoren im Kunststoffgehäuse nach TGL 38158 und TGL 33965" class="read-more" href="https://www.ddr-rft-elektronik.de/kondensatoren/ks-kondensatoren-im-kunststoffgehaeuse-nach-tgl-38158-und-tgl-33965/" aria-label="Mehr Informationen über KS Kondensatoren im Kunststoffgehäuse nach TGL 38158 und TGL 33965">Weiterlesen</a>]]></description>
										<content:encoded><![CDATA[<p><img fetchpriority="high" decoding="async" width="300" height="200" class="alignleft size-medium wp-image-254" src="https://www.ddr-rft-elektronik.de/wp-content/uploads/2014/06/IMG_6155-300x200.jpg" alt="KS-Kondensator nach TGL 33965" srcset="https://www.ddr-rft-elektronik.de/wp-content/uploads/2014/06/IMG_6155-300x200.jpg 300w, https://www.ddr-rft-elektronik.de/wp-content/uploads/2014/06/IMG_6155-600x400.jpg 600w, https://www.ddr-rft-elektronik.de/wp-content/uploads/2014/06/IMG_6155-1024x682.jpg 1024w, https://www.ddr-rft-elektronik.de/wp-content/uploads/2014/06/IMG_6155.jpg 1920w" sizes="(max-width: 300px) 100vw, 300px" />Die <strong>KS Kondensatoren</strong> nach <strong>TGL 33965</strong> und <strong>TGL 38158</strong> sind <strong>Polystyrolkondensatoren</strong> in einem prismatischen Kunststoffgehäuse. Die Kondensatoren sind hochwertige Passivbauelemente der Elektronik und waren für die Anwendung in der kommerziellen Funk- und Fernmeldetechnik vorgesehen. Durch den Einbau der Kondensatorwickel in dem epoxidharzvergossenem Kunststoffbecher sind die KS-Kondensatoren sehr gut gegen Umwelteinflüsse geschützt, was sich sehr positiv auf die Konstanz der Kennwerte auswirkt.<span id="more-252"></span>Entsprechend der Anforderungen des Einsatzgebietes der Kondensatoren nach TGL 33965 und TGL 38158 wurden diese mit feingestuften Nennkapazitätswerten der Reihe E192 und zusätzlich mit kleinen Kapazitätstoleranzen gefertigt. Als Belag der Kondensatoren wurde Zinnfolie eingesetzt, was zu einem besonders kontaktsicheren und induktionsarmen Wickelaufbau sowie einer guten Langzeitstabilität der Kapazität führte.</p>
<h2>Unterschiede der KS Kondensatoren TGL 33965 und TGL 38158</h2>
<p>Die Kondensatoren der TGL 38158 sind bei einzuhaltenden Grenzwerten schwalllötbar. Die KS Kondensatoren der TGL 33965 unterscheiden sich von denen der TGL 38158 durch die Bauform, den erweiterten Nennkapazitätsbereich sowie die Möglichkeit der Herstellung als Doppelkapazitäten im Bereich 2x100pF bis 2x9090pF. Weiterhin besitzen diese Kondensatoren eine höhere Langzeitstabilität der Nennkapazität. Bei den Kondensatoren der TGL 33965 gibt es für ausgewählte Werte die Bauform P, welche an der Stelle der Polystyrolfolie ein Dieelektrikum aus Polypropylenfolie besitzt. Die Kondensatoren wurden in den folgenden Bauformen gefertigt:</p>
<ul>
<li>Bauform A und Bauform B &#8211; beinhalten Einfachkapazitäten</li>
<li>Bauform C und Bauform D &#8211; enthalten Doppelkapazitäten</li>
<li>Bauform B und Bauform D unterscheiden sich dabei von A bzw. C bei einigen Kenngrößen durch bessere Werte (Toleranz, Temperaturkoeffizient &#8211; TK oder temperaturabhängige Kapazitätsänderung)</li>
</ul>
<p>Die Einzelkondensatoren der Doppelkapazitäten der Bauform C und Bauform D können auch unterschiedliche Nennkapazitäten der Reihe E192 aufweisen.</p>
<h2>Kennwerte der prismatischen KS Kondensatoren nach TGL 33965</h2>
<table>
<tbody>
<tr>
<td><strong>Kenngröße</strong></td>
<td><strong>Kennwert</strong></td>
<td><strong>Bemerkungen</strong></td>
</tr>
<tr>
<td style="vertical-align: top;">Nennspannung U<sub>N</sub></td>
<td style="text-align: center;">25V und 63V</td>
<td style="text-align: center;"></td>
</tr>
<tr>
<td style="vertical-align: top;" rowspan="2">zulässige <a title="Was bedeutet DC – GS – AC – WS" href="https://www.ddr-rft-elektronik.de/allgemein/was-bedeutet-dc-gs-ac-ws/">Wechselspannung WS</a> U<sub>eff</sub></td>
<td style="text-align: center;">15V</td>
<td style="text-align: center;">für U<sub>N</sub> = 25V</td>
</tr>
<tr>
<td style="text-align: center;">40V</td>
<td style="text-align: center;">für U<sub>N</sub> = 63V</td>
</tr>
<tr>
<td style="vertical-align: top;">zulässiger Wechselstrom I<sub>eff</sub></td>
<td style="text-align: center;">≤0,2A</td>
<td style="text-align: center;"></td>
</tr>
<tr>
<td style="vertical-align: top;" rowspan="2">Nennkapazitäten C<sub>N</sub></td>
<td style="text-align: center;">100pF bis 27000pF</td>
<td style="text-align: center;">U<sub>N</sub> = 63V, Reihe E192</td>
</tr>
<tr>
<td style="text-align: center;"> 9200pF bis 56000pF</td>
<td style="text-align: center;">U<sub>N</sub> = 25V, Reihe E192</td>
</tr>
<tr>
<td style="vertical-align: top;">Nennkapazitätstoleranz</td>
<td style="text-align: center;">±0,5%, ±1%, ±2%, ±5%</td>
<td style="text-align: center;"></td>
</tr>
<tr>
<td style="vertical-align: top;" rowspan="6">Verlustfaktor tan δ</td>
<td style="text-align: center;">≤ 2 * 10<sup>-4</sup></td>
<td style="text-align: center;">Bauform A, B, C, D<br />
f = 1kHz</td>
</tr>
<tr>
<td style="text-align: center;">≤ 3 * 10<sup>-4</sup></td>
<td style="text-align: center;">Bauform A, B, C, D<br />
für C<sub>N</sub> ≤ 1000pF und f = 100kHz</td>
</tr>
<tr>
<td style="text-align: center;">≤ 8 * 10<sup>-4</sup></td>
<td style="text-align: center;">Bauform A, C<br />
für C<sub>N</sub> ≤ 10000pF und f = 100kHz</td>
</tr>
<tr>
<td style="text-align: center;">≤ 5 * 10<sup>-4</sup></td>
<td style="text-align: center;">Bauform B, D<br />
für C<sub>N</sub> ≤ 10000pF und f = 100kHz</td>
</tr>
<tr>
<td style="text-align: center;">≤ 8 * 10<sup>-4</sup></td>
<td style="text-align: center;">Bauform A, C<br />
für C<sub>N</sub> ≤ 1000pF und f = 1MHz</td>
</tr>
<tr>
<td style="text-align: center;">≤ 5 * 10<sup>-4</sup></td>
<td style="text-align: center;">Bauform B, D<br />
für C<sub>N</sub> ≤ 1000pF und f = 1MHz</td>
</tr>
<tr>
<td rowspan="2">Isolationswiderstand</td>
<td style="text-align: center;">1 * 10<sup>11</sup> Ω</td>
<td style="text-align: center;">Bauform A, C, D, P</td>
</tr>
<tr>
<td style="text-align: center;">2 * 10<sup>11</sup> Ω</td>
<td style="text-align: center;">Bauform B</td>
</tr>
<tr>
<td style="vertical-align: top;" rowspan="8">Temperaturkoeffizient α<sub>c</sub></td>
<td style="text-align: center;">-(25 bis 150) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">Bauform A, C<sub>N</sub> ≤ 2200pF</td>
</tr>
<tr>
<td style="text-align: center;">-(75 bis 200) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">Bauform A, C<sub>N</sub> &gt; 2200pF</td>
</tr>
<tr>
<td style="text-align: center;">-(50 bis 110) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">Bauform B, C<sub>N</sub> ≤ 800pF</td>
</tr>
<tr>
<td style="text-align: center;">-(75 bis 135) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">Bauform B, C<sub>N</sub> ≤ 4000pF</td>
</tr>
<tr>
<td style="text-align: center;">-(100 bis 160) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">Bauform B, 20nF &lt; C<sub>N</sub> ≤ 82,5nF</td>
</tr>
<tr>
<td style="text-align: center;">-(25 bis 175) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">Bauform C</td>
</tr>
<tr>
<td style="text-align: center;">-(50 bis 140) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">Bauform D</td>
</tr>
<tr>
<td style="text-align: center;">-(230 bis 400) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">Bauform P</td>
</tr>
<tr>
<td style="vertical-align: top;" rowspan="2">zeitliche Inkonstanz der Kapazität</td>
<td style="text-align: center;">≤ ±(0,2% + 0,5pF)</td>
<td style="text-align: center;">nach einem Jahr</td>
</tr>
<tr>
<td style="text-align: center;">≤ ±1%</td>
<td style="text-align: center;">Bauform P</td>
</tr>
<tr>
<td>Klimaprüfklasse</td>
<td style="text-align: center;">40/070/21</td>
<td style="text-align: center;"></td>
</tr>
</tbody>
</table>
<h2>Kennwerte der prismatischen Kondensatoren der TGL 38158</h2>
<table>
<tbody>
<tr>
<td><strong>Kenngröße</strong></td>
<td><strong>Kennwert</strong></td>
<td><strong>Bemerkungen</strong></td>
</tr>
<tr>
<td style="vertical-align: top;">Nennspannung U<sub>N</sub></td>
<td style="text-align: center;">25V und 63V</td>
<td style="text-align: center;"></td>
</tr>
<tr>
<td style="vertical-align: top;" rowspan="2">zulässige <a title="Was bedeutet DC – GS – AC – WS" href="https://www.ddr-rft-elektronik.de/allgemein/was-bedeutet-dc-gs-ac-ws/">Wechselspannung WS</a> U<sub>eff</sub></td>
<td style="text-align: center;">15V</td>
<td style="text-align: center;">für U<sub>N</sub> = 25V</td>
</tr>
<tr>
<td style="text-align: center;">40V</td>
<td style="text-align: center;">für U<sub>N</sub> = 63V</td>
</tr>
<tr>
<td style="vertical-align: top;">zulässiger Wechselstrom I<sub>eff</sub></td>
<td style="text-align: center;">≤0,2A</td>
<td style="text-align: center;"></td>
</tr>
<tr>
<td style="vertical-align: top;" rowspan="2">Nennkapazitäten C<sub>N</sub></td>
<td style="text-align: center;">180pF bis 47000pF</td>
<td style="text-align: center;">U<sub>N</sub> = 25V, Reihe E192</td>
</tr>
<tr>
<td style="text-align: center;"> 180pF bis 18000pF</td>
<td style="text-align: center;">U<sub>N</sub> = 63V, Reihe E192</td>
</tr>
<tr>
<td style="vertical-align: top;">Nennkapazitätstoleranz</td>
<td style="text-align: center;">±1%, ±2%, ±5%</td>
<td style="text-align: center;"></td>
</tr>
<tr>
<td style="vertical-align: top;" rowspan="4">Verlustfaktor tan δ</td>
<td style="text-align: center;">≤ 2 * 10<sup>-4</sup></td>
<td style="text-align: center;">für C<sub>N</sub> ≤ 1000pF und f ≤ 10kHz</td>
</tr>
<tr>
<td style="text-align: center;">≤ 10 * 10<sup>-4</sup></td>
<td style="text-align: center;">für C<sub>N</sub> ≤ 1000pF und f = 1MHz</td>
</tr>
<tr>
<td style="text-align: center;">≤ 4 * 10<sup>-4</sup></td>
<td style="text-align: center;">für C<sub>N</sub> &gt; 22000pF und f = 1kHz</td>
</tr>
<tr>
<td style="text-align: center;">≤ 8 * 10<sup>-4</sup></td>
<td style="text-align: center;">für C<sub>N</sub> &gt; 22000pF und f = 100kHz</td>
</tr>
<tr>
<td>Isolationswiderstand</td>
<td style="text-align: center;">1 * 10<sup>11</sup> Ω</td>
<td style="text-align: center;"></td>
</tr>
<tr>
<td>Temperaturkoeffizient α<sub>c</sub></td>
<td style="text-align: center;">-(25 bis 150) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">C<sub>N</sub> ≤ 796pF</td>
</tr>
<tr>
<td></td>
<td style="text-align: center;">-(40 bis 160) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">C<sub>N</sub> ≤ 22000pF</td>
</tr>
<tr>
<td></td>
<td style="text-align: center;">-(70 bis 170) * 10<sup>-6</sup> /K</td>
<td style="text-align: center;">C<sub>N</sub> &gt; 22000pF</td>
</tr>
<tr>
<td>zeitliche Inkonstanz der Kapazität</td>
<td style="text-align: center;">≤ ±(0,3% + 0,4pF)</td>
<td style="text-align: center;">nach einem Jahr</td>
</tr>
<tr>
<td>Klimaprüfklasse</td>
<td style="text-align: center;">40/070/21</td>
<td style="text-align: center;"></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
